Powered by GoogleTranslate

Inspection Detail

Inspection: 14738777 - Preway Industries Inc

Inspection Information - Office: Indiana Department Of Labor

 

Inspection Nr: 14738777
Report ID: 0551800
Date Opened: 03/05/1985

Site Address:
Preway Industries Inc
819 E Franklin St
Evansville, IN 47704

Mailing Address:
P O Box 534, Evansville, IN 47704

Union Status: Union

SIC:3585

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/20/1985

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 04/16/1985


Related Activity
Type Activity Nr Safety Health
Accident 360581946
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $320 $0 $0 $0 $0 $320
Current Penalty $320 $0 $0 $0 $0 $320
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100217 C01 I 04/01/1985 03/20/1985 $320 $320 $0 -  
2. 01001B Serious 19100217 C03 IV 04/01/1985 03/20/1985 $0 $0 $0 -  
3. 01001C Serious 19100217 C03 VIIIC 04/01/1985 03/20/1985 $0 $0 $0 -  
4. 01001D Serious 19100217 E01 I 04/01/1985 04/17/1985 $0 $0 $0 -  
5. 01001E Serious 19100217 E01 II 04/01/1985 04/17/1985 $0 $0 $0 -  

Investigation Summary

Investigation Nr: 731067
Event: 02/20/1985
Employee's fingers amputated in mechanical power press

At 2:12 p.m. on February 20, 1985, Employee #1, a die-setter, was operating a Cleveland full revolution mechanical power press, serial #8343, property #16416. The press had not been tripping properly. The employee had his right hand in the point of operation when he tripped the press by punching the button on the air valve to the single stroke mechanism. His index, middle, and ring fingers and the tip of his thumb were amputated. He was taken to Deaconess Hospital in Evansville, IL, and then transferred to Jewish Hospital in Louisville, KY. The accident occurred as a result of failure to use point of operation guarding, failure to perform regular inspections of the press, and failure to make necessary repairs before the press was operated.

Keywords: AMPUTATED, INADEQUATE MAINT, POWER PRESS, FINGER, WORK RULES, THUMB, POINT OF OPERATION, PRESS OPERATOR, UNGUARDED, INATTENTION

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 14738777 Hospitalized injury Amputation Punching and stamping press machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close