Inspection Detail
Inspection: 1473682.015 - Verigent, Llc
Inspection Information - Office: Sacramento District Office
Site Address:
Verigent, Llc
7000 Power Line Rd.
Sacramento, CA 95837
Mailing Address:
9920 Kincey Ave. Ste. #210, Huntersville, NC 28078
Union Status: NonUnion
SIC:
NAICS: 238210/Electrical Contractors
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 07/20/2020
Emphasis:
Case Closed: 08/18/2025
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1580834 | ||
Inspection | 1473757 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 6 | 8 | |||
Current Violations | 1 | 7 | 8 | |||
Initial Penalty | $45,000 | $0 | $0 | $5,060 | $0 | $50,060 |
Current Penalty | $18,000 | $0 | $0 | $14,060 | $0 | $32,060 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 1509(A) | 08/04/2020 | $450 | $450 | $0 | Z - Issued | |||
2. | 01002 | Other | 1509(A) | 08/04/2020 | $1,125 | $1,125 | $0 | Z - Issued | |||
3. | 01003 | Other | 1509(B) | 08/04/2020 | $505 | $505 | $0 | Z - Issued | |||
4. | 01004 | Other | 1510(B) | 08/04/2020 | $1,125 | $1,125 | $0 | Z - Issued | |||
5. | 01005 | Other | 3395(I) | 08/04/2020 | $505 | $505 | $0 | Z - Issued | |||
6. | 01006 | Other | 3648(B) | 08/04/2020 | $1,350 | $1,350 | $0 | Z - Issued | |||
7. | 02001 | Serious | 3638(D) | 08/04/2020 | $18,000 | $22,500 | $0 | 10/09/2020 | O - Administrative Law Judge Order | ||
8. | 03001 | Other | 3648(L) | 08/04/2020 | $9,000 | $22,500 | $0 | 10/09/2020 | O - Administrative Law Judge Order |
Investigation Summary
At 1:10 p.m. on April 29, 2020, Employee #1, employed by a staffing agency, was installing data cable at a multiemployer construction project, a single-story commercial building. He was operating a JLG 450AJ aerial lift and working from the elevated basket. As he moved the lift in reverse, approximately 40 feet above the ground, he struck a perpendicular steel joist. Employee #1's neck was pinned between the basket's guardrail and the joist, and he was asphyxiated.
Keywords: Aerial Lift, Asphyxiated, Caught Between, Construction, Crushed, Equipment Operator, Guardrail, Installing, Joist, Neck, Pinned, Struck Against
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1473682.015 | 30 | M | Fatality | Construction laborers |