Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1472608.015 - Okuley'S Pharmacy & Home Medical, Inc.

Inspection Information - Office: Toledo Area Office

 

Inspection Nr: 1472608.015
Report ID: 0524700
Date Opened: 04/17/2020

Site Address:
Okuley'S Pharmacy & Home Medical, Inc.
1201 E. Second St.
Defiance, OH 43512

Mailing Address:
1201 E. Second St., Defiance, OH 43512

Union Status: NonUnion

SIC:

NAICS: 446110/Pharmacies and Drug Stores


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/17/2020

Emphasis:

Case Closed: 08/25/2020


Related Activity
Type Activity Nr Safety Health
Referral 1573270 Yes Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 2 2
Initial Penalty $14,651 $0 $0 $0 $0 $14,651
Current Penalty $4,396 $0 $0 $0 $0 $4,396
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100106 E06 II 06/10/2020 06/19/2020 $2,550 $3,856 $0 I - Informal Settlement  
2. 01001B Serious 19100307 C 06/10/2020 06/17/2020 $0 $5,398 $0 I - Informal Settlement  
3. 01002A Serious 19100133 A01 06/10/2020 06/19/2020 $1,846 $2,313 $0 I - Informal Settlement  
4. 01002B Serious 19101200 H01 06/10/2020 06/19/2020 $0 $0 $0 I - Informal Settlement  
5. 01004A Serious 19101200 E01 06/10/2020 06/26/2020 $0 $3,084 $0 I - Informal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 125433.015
Event: 04/15/2020
Employee making sanitizer sustains burns when alcohol ignite

At 4:30 p.m. on Aprill 15, 2020, an employee working as a technician for a pharmacy was setting up a filtering system for ethyl alcohol while making sanitizer. In order to mitigate a foul odor from the ethyl alcohol, the employee used a Liberty Model 331 electric transfer pump to transfer the alcohol from one bucket through tubing and a charcoal filter to another bucket. The alcohol began spraying out of the setup when the employee poured it into the prime port and subsequently ignited. The liquid had sprayed on the employee resulting in burns. A coworker (owner) witnessed the incident. The electric transfer pump was not intended to transfer flammable liquids. The employee was hospitalized to treat second-degree burns to his hands, arms, and face.

Keywords: Alcohol, Arm, Bucket , Burn, Chemical, Chemical Vapor, Electric Pump, Ethyl Alcohol, Face, Fire, Flammable Liquid, Flammable Vapors, Hand, Hazard Communication, Ignite, Ignition, Skin, Splashed

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1472608.015 49 M Hospitalized injury Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close