Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1472292.015 - Aguila Contractor, Llc

Inspection Information - Office: Tampa Area Office

 

Inspection Nr: 1472292.015
Report ID: 0420600
Date Opened: 11/23/2019

Site Address:
Aguila Contractor, Llc
2404 Metfield Dr.
Melbourne, FL 32940

Mailing Address:
1080 S Hoagland Blvd Lot74, Kissimmee, FL 34741

Union Status: NonUnion

SIC:

NAICS: 238350/Finish Carpentry Contractors


Inspection Type: Planned

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 04/30/2020

Emphasis: P:Fall, L:Fall

Case Closed: 09/18/2023


Related Activity
Type Activity Nr Safety Health
Inspection 1447025 Yes
Inspection 1447010 Yes
Inspection 1447030 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $16,192 $0 $0 $0 $0 $16,192
Current Penalty $16,192 $0 $0 $0 $0 $16,192
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260251 A01 05/08/2020 $4,048 $4,048 $0 Z - Issued  
2. 01002 Serious 19261425 B 05/08/2020 $4,048 $4,048 $0 Z - Issued  
3. 01003 Serious 19261425 C01 05/08/2020 $4,048 $4,048 $0 Z - Issued  
4. 01004 Serious 19261425 C03 05/08/2020 $4,048 $4,048 $0 Z - Issued  

Investigation Summary

Investigation Nr: 125828.015
Event: 11/23/2019
Two employees incur multiple injuries when suspended roof se

At 10:30 a.m. on November 23, 2019, two employees were working for a framing and drywall contractor. They were working at a multi-employer site. They were carpenters, part of a project of new work on or an addition to a six-story building, a hotel. They were installing bracing on the underside of a roof section that was suspended in the air from a crane. The roof section was 32 feet, 3 inches wide and 32 feet, 3 inches long (9.8 meters by 9.8 meters). It weighed 10,000 lbs. (4,500 kg). Four landscape timbers were being used as the rigging to lift the roof section. The landscape timbers had been run along the top chord of cold steel formed metal trusses, with no rigging securely holding the roof section in place. The landscape timbers had not been inspected. The load had not been rigged by a qualified rigger. The landscape timbers broke under the weight of the roof section, and the roof section fell from the crane. The roof section crushed the two employees They suffered fractures in the pelvis, legs, feet, and vertebrae. They were hospitalized. Investigation number 125828 brought up four entities, each with its own inspection number. Brevard Framing and Drywall, LLC had inspection number 1447010. PINKERTON & LAWS OF FLORIDA INC. had inspection number 1447025. Spinning Crane Works LLC had inspection number 1447030. AGUILA CONTRACTOR, LLC had inspection number 1472292. This account was based on the details for Brevard Framing and Drywall, LLC.

Keywords: Bracing, Broken Bone, Commercial Building, Construction, Crane, Crushed, Equipment Failure, Falling Object, Foot, Fracture, Hotel, Inspecting, Inspection, Leg, Lifting, Multi-employer Worksite, Multiemployer, Pelvis, Rigging, Roof, Roof Panel, Struck By, Suspended Load, Vertebra

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1472292.015 43 M Hospitalized injury Carpenter
2 1472292.015 41 M Hospitalized injury Carpenters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close