Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1468775.015 - Delaware City Refining Company, Llc

Inspection Information - Office: Wilmington Area Office

 

Inspection Nr: 1468775.015
Report ID: 0317300
Date Opened: 03/12/2020

Site Address:
Delaware City Refining Company, Llc
4550 Wrangle Hill Road
Delaware City, DE 19706

Mailing Address:
4550 Wrangle Hill Road, Delaware City, DE 19706

Union Status: Union

SIC:

NAICS: 324110/Petroleum Refineries


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 09/11/2020

Emphasis: N:Chemnep

Case Closed: 01/14/2025


Related Activity
Type Activity Nr Safety Health
Referral 1551884 Yes Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 10 2 12
Current Violations 10 10
Initial Penalty $132,049 $269,874 $0 $0 $0 $401,923
Current Penalty $401,923 $0 $0 $0 $0 $401,923
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100119 D03 II 09/11/2020 10/29/2020 $17,982 $13,494 $0 10/02/2020 F - Formal Settlement  
2. 01002 Serious 19100119 E03 III 09/11/2020 10/29/2020 $15,994 $13,494 $0 10/02/2020 F - Formal Settlement  
3. 01003 Serious 19100119 E03 V 09/11/2020 10/29/2020 $0 $13,494 $0 10/02/2020 F - Formal Settlement Citation has been deleted.
4. 01004 Serious 19100119 E03 VI 09/11/2020 10/29/2020 $0 $13,494 $0 10/02/2020 F - Formal Settlement Citation has been deleted.
5. 01005 Serious 19100119 F01 I D 09/11/2020 10/29/2020 $15,994 $13,494 $0 10/02/2020 F - Formal Settlement  
6. 01006 Serious 19100119 F01 II A 09/11/2020 10/29/2020 $15,994 $13,494 $0 10/02/2020 F - Formal Settlement  
7. 01007 Serious 19100119 G01 I 09/11/2020 10/29/2020 $15,994 $13,494 $0 10/02/2020 F - Formal Settlement  
8. 01008 Serious 19100119 N 09/11/2020 10/29/2020 $15,994 $13,494 $0 10/02/2020 F - Formal Settlement  
9. 01009A Serious 19100120 Q06 I 09/11/2020 10/29/2020 $15,994 $13,494 $0 10/02/2020 F - Formal Settlement  
10. 01009B Serious 19100120 Q06 II 09/11/2020 10/29/2020 $0 $0 $0 10/02/2020 F - Formal Settlement  
11. 01009C Serious 19100120 Q08 I 09/11/2020 10/29/2020 $0 $0 $0 10/02/2020 F - Formal Settlement  
12. 01010 Serious 19100132 D01 I 09/11/2020 10/07/2020 $13,103 $10,603 $0 10/02/2020 F - Formal Settlement  
13. 02001 Serious 19100119 E05 09/11/2020 10/29/2020 $137,437 $134,937 $0 10/02/2020 F - Formal Settlement  
14. 02002A Serious 19100119 J02 09/11/2020 10/29/2020 $137,437 $134,937 $0 10/02/2020 F - Formal Settlement  
15. 02002B Serious 19100119 J04 I 09/11/2020 10/29/2020 $0 $0 $0 10/02/2020 F - Formal Settlement  
16. 02002C Willful 19100119 J04 II 09/11/2020 10/29/2020 $0 $0 $0 10/02/2020 F - Formal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 124730.015
Event: 03/11/2020
Two employees suffer serious burns in desulfurization unit f

At 1:30 p.m. on March 11, 2020, two employees were responding to a heater-temperature alarm transmitted to the control room from a heater tube thermocouple. Initially, just prior to activating a shutdown response, multiple operators reported a more than usual smoke volume emitting from the smokestack for this heater. It was reported that an even greater smoke volume emitted. Then, there was a sudden deflagration. The two employees, who at this time were responding to the heater-temperature alarm in the field and positioned right next to the heater peering into the heater's port holes, were thrown by the blast pressure, sustaining serious burn injuries from the fire. The direct equipment cause of this fire was due to the failure of a specific heater tube located in the convection section of the heater, the same tube, tube #66, that had failed in the past. The heater tube ruptured, spewing flammable distillates into the open space within the active, flaming heater box that ignited, erupting into an uncontained fire, eventually contained, and then extinguished by DCRC's fire brigade. One employee had serious burns to the face, neck, back and one hand; the other employee had serious burns to the face and neck. Both employees were hospitalized.

Keywords: Alarm, Back, Blasting, Burn, Face, Fire, Fire Brigade, Flammable Liquid, Flammable Vapors, Hand, Heater, Ignite, Neck, Operator, Refinery, Smoke

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1468775.015 31 M Hospitalized injury Chemical technicians
2 1468775.015 45 M Hospitalized injury Chemical technicians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close