Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1467793.015 - Altium Packaging Lp

Inspection Information - Office: Atlanta West Area Office

 

Inspection Nr: 1467793.015
Report ID: 0418200
Date Opened: 03/05/2020

Site Address:
Altium Packaging Lp
6220 Duquense Dr. Sw
Atlanta, GA 30336

Mailing Address:
2500 Windy Ridge Pkwy Suite 1400, Atlanta, GA 30339

Union Status: NonUnion

SIC:

NAICS: 326160/Plastics Bottle Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 03/05/2020

Emphasis: N:Amputate

Case Closed: 06/11/2020


Related Activity
Type Activity Nr Safety Health
Referral 1547793 Yes
Inspection 1467803 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $12,145 $0 $0 $0 $0 $12,145
Current Penalty $8,502 $0 $0 $0 $0 $8,502
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100212 A01 05/04/2020 06/05/2020 $8,502 $12,145 $0 I - Informal Settlement  
2. 02001 Other 19101200 H01 05/04/2020 05/29/2020 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 124586.015
Event: 02/26/2020
Employee amputates finger when pulled into ejection belt con

At 6:30 p.m. on February 26, 2020, an employee working as a machine operator for a plastics bottle manufacturer was operating a detabber machine. While attempting to remove jammed plastic bottles from the machine, his glove got caught and was pulled into the ejection belt conveyor along with his hand. The employee amputated his left ring finger and received medical treatment without hospitalization.

Keywords: Amputated, Amputation, Belt Conveyor, Catch Point, Caught By, Conveyor, Finger, Glove, Hand, Instantaneous amputation, Jammed, Machine Guarding, Machine operator, Plastic, Plastic Mfg, Pulled In, Safety Device, Traumatic Amputation

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1467793.015 64 M Non Hospitalized injury Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close