Inspection Detail
Inspection: 1467269.015 - Kobo Products, Inc.
Inspection Information - Office: Avenel Area Office
Site Address:
Kobo Products, Inc.
690 Montrose Avenue
South Plainfield, NJ 07080
Mailing Address:
3474 S. Clinton Avenue, South Plainfield, NJ 07080
Union Status: NonUnion
SIC:
NAICS: 325620/Toilet Preparation Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 07/08/2020
Emphasis:
Case Closed: 08/17/2020
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1548625 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $8,848 | $0 | $0 | $0 | $0 | $8,848 |
Current Penalty | $6,636 | $0 | $0 | $0 | $0 | $6,636 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100106 E06 I | 07/31/2020 | $6,636 | $8,848 | $0 | I - Informal Settlement |
Investigation Summary
At 5:30 a.m. on February 24, 2020, an employee was scrubbing interior surfaces of a mix tank with 1-2 gallons of petroleum naphtha using a Teflon bristle brush when a suspected static discharge ignited the flammable solvent vapor within the tank. The employee was hospitalized to treat second degree burns to his face and hands.
Keywords: Burn, Cleaning, Face, Fire, Hand, Ignite, Petroleum Naphtha, Static Electricity, Tank
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1467269.015 | 42 | M | Hospitalized injury | Chemical technicians |