Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1465587.015 - Clark Dietrich

Inspection Information - Office: Dallas Area Office

 

Inspection Nr: 1465587.015
Report ID: 0626300
Date Opened: 02/24/2020

Site Address:
Clark Dietrich
10340 Denton Dr.
Dallas, TX 75220

Mailing Address:
10340 Denton Dr., Dallas, TX 75220

Union Status: NonUnion

SIC:

NAICS: 332312/Fabricated Structural Metal Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/24/2020

Emphasis: N:Amputate, L:Fabmetsh

Case Closed: 04/01/2020


Related Activity
Type Activity Nr Safety Health
Referral 1546209 Yes
Case Status: CLOSED

Investigation Summary

Investigation Nr: 124319.015
Event: 02/21/2020
Employee amputates finger in lathe

At 9:30 a.m. on February 21, 2020, an employee was working on a lathe. The employee's finger was caught in the point of operation. The employee's right index finger was amputated, and he was hospitalized.

Keywords: Amputated, Amputation, Caught In, Finger, Lathe, Point Of Operation

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1465587.015 60 F Hospitalized injury
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.