Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1463882.015 - The Fishel Company

Inspection Information - Office: Cleveland Area Office

 

Inspection Nr: 1463882.015
Report ID: 0522300
Date Opened: 02/19/2020

Site Address:
The Fishel Company
State Route 18/21
Fairlawn, OH 44333

Mailing Address:
1366 Dublin Road, Columbus, OH 43215

Union Status: NonUnion

SIC:

NAICS: 237130/Power and Communication Line and Related Structures Construction


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/19/2020

Emphasis:

Case Closed: 06/29/2020


Related Activity
Type Activity Nr Safety Health
Referral 1543069 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 1 1
Initial Penalty $23,132 $0 $0 $0 $0 $23,132
Current Penalty $0 $0 $0 $13,494 $0 $13,494
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Other 19100268 B07 03/30/2020 06/30/2020 $13,494 $11,566 $0 I - Informal Settlement  
2. 01001B Other 19100268 N01 I 03/30/2020 06/30/2020 $0 $11,566 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 124120.015
Event: 02/11/2020
Employee is shocked while installing telecommunication lines

At 1:45 p.m. on February 11, 2020, Employee #1 was part of a crew installing fiber optic cable on poles near energized overhead power lines. While installing the fiber optic cable, one section of the fiber became caught in the other telecommunication lines previously installed on the poles. Employee #1 grabbed the lines to try and separate it but the strand line bounced and contacted the 7.2kv power line located above the fiber. Employee #1 suffered electric shock injuries and was hospitalized for two days.

Keywords: Contact, Electric Shock, Energized, Hospital, Installing, KV (Kilovolts), Optical Fiber Cable, Overhead Power Line, Power Lines, Telecom Work, Utility Pole

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1463882.015 25 M Hospitalized injury Installers And Repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close