Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1463362.015 - Combined Systems, Inc.

Inspection Information - Office: Erie Area Office

 

Inspection Nr: 1463362.015
Report ID: 0336000
Date Opened: 02/14/2020

Site Address:
Combined Systems, Inc.
388 Kinsman Road
Jamestown, PA 16134

Mailing Address:
388 Kinsman Road, Jamestown, PA 16134

Union Status: NonUnion

SIC:

NAICS: 332993/Ammunition (except Small Arms) Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 08/04/2020

Emphasis: N:Chemnep

Case Closed: 06/28/2022


Related Activity
Type Activity Nr Safety Health
Referral 1544512 Yes Yes
Inspection 1467293 Yes
Inspection 1463350 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $11,798 $0 $0 $0 $0 $11,798
Current Penalty $6,500 $0 $0 $0 $0 $6,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100119 E06 08/12/2020 07/01/2022 $3,250 $5,899 $0 P - Petition to Mod Abatement  
2. 01002 Serious 19100119 O01 08/12/2020 07/01/2021 $3,250 $5,899 $0 P - Petition to Mod Abatement  
3. 02001 Other 19100119 J04 IV 08/12/2020 09/29/2020 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 124070.015
Event: 02/14/2020
Employee sustains burns to hand, face due to electrostatic d

At 9:30 a.m. on February 14, 2020, an employee working as a laborer for a ammunition manufacturer had just rejected a powder mixture during a quality control check. The employee prepared to dump the mixture into a container containing mineral oil when an electrostatic discharge occurred between the employee and the pouring operation. A primary flash fire occurred which caused a secondary flash fire in two machines behind the employee. The employee sustained burns to his hands and face and received medical treatment without hospitalization.

Keywords: Ammunition, Burn, Clothing, Electrostatic, Face, Fire, Flame-Resistant Clothing (FRC), Flash, Flying Object, Hand, Head, High Temperature, PPE, PPE Hazard Assessment, Protective Clothing, Struck By

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1463362.015 30 M Non Hospitalized injury
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.