Inspection Detail
Inspection: 1463362.015 - Combined Systems, Inc.
Inspection Information - Office: Erie Area Office
Site Address:
Combined Systems, Inc.
388 Kinsman Road
Jamestown, PA 16134
Mailing Address:
388 Kinsman Road, Jamestown, PA 16134
Union Status: NonUnion
SIC:
NAICS: 332993/Ammunition (except Small Arms) Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 08/04/2020
Emphasis: N:Chemnep
Case Closed: 06/28/2022
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1544512 | Yes | Yes |
Inspection | 1467293 | Yes | |
Inspection | 1463350 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 1 | 3 | |||
Current Violations | 2 | 1 | 3 | |||
Initial Penalty | $11,798 | $0 | $0 | $0 | $0 | $11,798 |
Current Penalty | $6,500 | $0 | $0 | $0 | $0 | $6,500 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100119 E06 | 08/12/2020 | 07/01/2022 | $3,250 | $5,899 | $0 | P - Petition to Mod Abatement | ||
2. | 01002 | Serious | 19100119 O01 | 08/12/2020 | 07/01/2021 | $3,250 | $5,899 | $0 | P - Petition to Mod Abatement | ||
3. | 02001 | Other | 19100119 J04 IV | 08/12/2020 | 09/29/2020 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
At 9:30 a.m. on February 14, 2020, an employee working as a laborer for a ammunition manufacturer had just rejected a powder mixture during a quality control check. The employee prepared to dump the mixture into a container containing mineral oil when an electrostatic discharge occurred between the employee and the pouring operation. A primary flash fire occurred which caused a secondary flash fire in two machines behind the employee. The employee sustained burns to his hands and face and received medical treatment without hospitalization.
Keywords: Ammunition, Burn, Clothing, Electrostatic, Face, Fire, Flame-Resistant Clothing (FRC), Flash, Flying Object, Hand, Head, High Temperature, PPE, PPE Hazard Assessment, Protective Clothing, Struck By
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1463362.015 | 30 | M | Non Hospitalized injury |