Powered by GoogleTranslate

Inspection Detail

Inspection: 14627616 - Kammann Development

Inspection Information - Office: Arizona Division Of Occupational Safety And Health (Adosh)

 

Inspection Nr: 14627616
Report ID: 0950411
Date Opened: 07/25/1984

Site Address:
Kammann Development
1342 23rd Drive
Yuma, AZ 85364

Mailing Address:
755 W 28th Street, Yuma, AZ 85364

Union Status: NonUnion

SIC:1521

NAICS: 0 


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 08/02/1984

Planning Guide: Safety-Construction

Emphasis:

Case Closed: 06/03/2016


Related Activity
Type Activity Nr Safety Health
Accident 360578520
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $210 $0 $0 $0 $0 $210
Current Penalty $210 $0 $0 $0 $0 $210
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19260401 A01 08/10/1984 08/13/1984 $210 $210 $0 -  

Investigation Summary

Investigation Nr: 14565444
Event: 07/21/1984
ELECTRIC SHOCK - GROUND FAULT IN UNGROUNDED EQUIPMENT

AN EMPLOYEE WAS INSTALLING KITCHEN CABINETS IN A HOUSE THAT WAS UNDER CONSTRUCTION. ABOUT 200 FEET OF NONMETALLIC SHEATHED CABLE WAS WIRED TO A CIRCUIT BREAKER PANELBOARD FOR A HOUSE ACROSS THE STREET. THE CABLE RAN TO THE BACK YARD OF THE HOUSE UNDER CONSTRUCTION, WHERE A 100-FOOT, 3-CONDUCTOR EXTENSION CORD SET WAS PLUGGED INTO AN OUTLET BOX INSTALLED ON THE CABLE. THE ATTACHMENT PLUG ON THE EXTENSION CORD HAD BEEN REPLACED WITH A TWO-PRONG, NON-GROUNDING-TYPE PLUG. A 3/8-INCH DRILL ADAPTED FOR USE AS AN ELECTRIC SCREW DRIVER HAD A 3-CONDUCTOR POWER CORD WITH THE GROUNDING PRONG MISSING FROM ITS ATTACHMENT PLUG. THE ELECTRIC SCREW DRIVER WAS PLUGGED INTO THE EXTENSION CORD. TO PERFORM HIS JOB, THE EMPLOYEE WAS SITTING ON THE FLOOR, UNDERNEATH THE KITCHEN SINK, LEANING AGAINST A COPPER WATER PIPE. WHILE HE WAS HOLDING THE ELECTRIC SCREW DRIVER IN THIS POSITION, A GROUND FAULT OCCURRED WITHIN THE DRILL MOTOR ENERGIZING THE METAL CASE. THE EMPLOYEE WAS ELECTROCUTED.

Keywords: ELECTRICAL, ATTACHMENT PLUG, E C, GROUND FAULT, EQUIPMENT GROUNDING, TEMPORARY WIRING, CORD SET, ELECTROCUTED

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 14627616 Fatality Electric Shock Cabinet makers and bench carpenters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.