Inspection Detail
Inspection: 14624209 - Greer Minor Farms
Inspection Information - Office: Arizona Division Of Occupational Safety And Health (Adosh)
Site Address:
Greer Minor Farms
1 Mile West Of Litchfield On Northern 2/10 Mile No
Youngtown, AZ 85383
Mailing Address:
96th Avenue And Harrison Po Box 207, Tolleson, AZ 85353
Union Status: NonUnion
SIC:0191
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 03/05/1985
Emphasis:
Case Closed: 06/03/2016
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 360613582 |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $420 | $0 | $0 | $0 | $0 | $420 |
| Current Penalty | $420 | $0 | $0 | $0 | $0 | $420 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 230403 A | 03/11/1985 | 03/14/1985 | $420 | $420 | $0 | 04/01/1985 | F - Formal Settlement |
Investigation Summary
AN EMPLOYEE LIFTED A 6-INCH-DIAMETER ALUMINUM IRRIGATION PIPE (30 FEET, 4 INCHES LONG) ON ITS END TO REMOVE DIRT FROM ITS INTERIOR. THE PIPE CONTACTED A 7200-VOLT OVERHEAD POWER LINE, ELECTROCUTING THE EMPLOYEE. A SECOND EMPLOYEE POSITIONED ABOUT 12 FEET FROM THE FIRST WAS RESTACKING PIPE. HE RECEIVED AN ELECTRIC SHOCK AND BURNS ON HIS HANDS AND RIGHT FOOT WHEN ONE OF THEM ALSO CONTACTED THE POWER LINE.
Keywords: BURN, OVERHEAD POWER LINE, ELECTRICAL, AGRICULTURE, ELECTROCUTED, IRRIGATION PIPE, ELECTRIC SHOCK, E AG, HAND, INATTENTION
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 14624209 | Fatality | Electric Shock | Occupation not reported | ||
| 2 | 14624209 | Non Hospitalized injury | Electric Shock | Occupation not reported |
Translate