Inspection Detail
Inspection: 14618128 - Quadna Inc
Inspection Information - Office: Arizona Division Of Occupational Safety And Health (Adosh)
Site Address:
Quadna Inc
2929 West Williamsfield Rd
Chandler, AZ 85224
Mailing Address:
2055 E 17th St Po Box 41475, Tucson, AZ 85717
Union Status: NonUnion
SIC:3069
NAICS: 0
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/21/1984
Planning Guide: Safety-Construction
Emphasis:
Case Closed: 06/03/2016
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 360579726 |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 2 | 3 | |||
Current Violations | 1 | 2 | 3 | |||
Initial Penalty | $420 | $0 | $0 | $0 | $0 | $420 |
Current Penalty | $420 | $0 | $0 | $0 | $0 | $420 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19260404 B | 06/08/1984 | 06/11/1984 | $420 | $420 | $0 | - | ||
2. | 02001 | Other | 19260400 A | 06/08/1984 | 06/11/1984 | $0 | $0 | $0 | - | ||
3. | 02002 | Other | 19260402 A10 | 06/08/1984 | 06/11/1984 | $0 | $0 | $0 | - |
Investigation Summary
EMPLOYEE #1 WAS STANDING AT THE BOTTOM OF A SUMP TANK, USING A PAINT BRUSH ROLLER TO ROLL CARBON DISULFIDE (CS2) ONTO THE UNCURED RUBBER LINED SUMP TANK WALLS. EMPLOYEE #1 HAD BEEN ROLLING ON THE CS2 FOR APPROXIMATELY 10-15 MINUTES. THERE WAS AN OPEN PLASTIC BUCKET (APPROXIMATE CAPACITY OF 1 -2 GALLONS) OF CS2 IN THE TANK. THE TANK DIMENSIONS WERE APPROXIMATELY 11 FEET 4 1/2 INCHES LONG BY 6 FEET 3 INCHES WIDE BY 8 FEET 11 INCHES DEEP. EMPLOYEE #2 WAS OUTSIDE THE TANK, IN THE SOUTHEAST CORNER, TILTING A PORTABLE NONEXPLOSION PROOF FAN TOWARD THE BOTTOM OF THE TANK. EMPLOYEE #2 SAW FLAMES SHOOT UP OUT OF THE TANK. EMPLOYEE #1 SUSTAINED SEVERE BURNS OVER 86% OF HIS BODY. HE WAS HOSPITALIZED WITH SECOND AND THIRD DEGREE BURNS. EMPLOYEE #2 WAS TREATED AT THE HOSPITAL FOR BREATHING DIFFICULTIES. HE WAS RELEASED UNDER A PHYSICIANS CARE. NO HOSPITAL STAY WAS REQUIRED.
Keywords: BURN, CONFINED SPACE, SUMP TANK, FIRE, CARBON DISULFIDE
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 14618128 | Non Hospitalized injury | Other | Occupation not reported |