Inspection Detail
Inspection: 1459191.015 - Florida Progress, Llc
Inspection Information - Office: Tampa
Site Address:
Florida Progress, Llc
6742 Clifton Down Dr
Zephyrhills, FL 33542
Mailing Address:
139 E Fourth Street Mail Code 1305-Main, Cincinnati, OH 45202
Union Status: Union
SIC:
NAICS: 221122/Electric Power Distribution
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/21/2020
Emphasis: N:Trench
Close Case:08/07/2020
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1536606 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 4 | 1 | 5 | |||
Current Violations | 3 | 2 | 5 | |||
Initial Penalty | $53,976 | $0 | $0 | $0 | $0 | $53,976 |
Current Penalty | $20,241 | $0 | $0 | $6,747 | $0 | $26,988 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 19260021 B02 | 06/18/2020 | 08/05/2020 | $6,747 | $13,494 | $0 | I - Informal Settlement | ||
2. | 01002 | Serious | 19260651 J02 | 06/18/2020 | $6,747 | $13,494 | $0 | I - Informal Settlement | |||
3. | 01003 | Serious | 19260651 K01 | 06/18/2020 | $6,747 | $13,494 | $0 | I - Informal Settlement | |||
4. | 01004 | Serious | 19260652 A01 | 06/18/2020 | $6,747 | $13,494 | $0 | I - Informal Settlement | |||
5. | 02001 | Other | 19260651 C02 | 06/18/2020 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
At 11:30 a.m. on January 22, 2020 , an employee was working in an unprotected tr ench laying power lines when the trench collapsed on him. The employee was hospi talized to treat fractures to both his tibia and fibula.
Keywords:access/egress, caught in, competent person, construction, electric cable, excavation, falling object, fracture, inexperience, installing, insufficient supervision, leg, obstructed egress, ppe, ppe hazard assessment
# | Inspection | Age | Sex | Degree | Nature | Occupation |
---|---|---|---|---|---|---|
1 | 1459191.015 | Hospitalized injury | Installers And Repairers |