Inspection: 1454056.015 - Kraft Heinz Food Company

Inspection Information - Office: Modesto District Office

 

Inspection Nr: 1454056.015
Report ID: 0950624
Date Opened: 01/07/2020

Site Address:
Kraft Heinz Food Company
1905 Mchenry Avenue
Escalon, CA 95320

Mailing Address:
1905 Mchenry Avenue, Escalon, CA 95320

Union Status: Union

SIC:

NAICS: 311421/Fruit and Vegetable Canning


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 02/18/2020

Emphasis:

Case Closed: 02/18/2022


Related Activity
Type Activity Nr Safety Health
Accident 1531698
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 1 1
Initial Penalty $18,000 $0 $0 $0 $0 $18,000
Current Penalty $3,825 $0 $0 $0 $0 $3,825
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 3203(A) 02/18/2020 $3,825 $9,000 $0 03/04/2020 O - Administrative Law Judge Order  
2. 02001 Serious 3328(A)(2) 02/18/2020 $0 $9,000 $0 03/04/2020 O - Administrative Law Judge Order Citation has been deleted.

Investigation Summary

Investigation Nr: 123981.015
Event: 08/17/2019
Employee is hit by magnet in stomach and tears intestine

At approximately 7:00 p.m. on August 17, 2019, an employee noticed there was something wrong with the line after line 8 startup. There was not enough product flowing (the mixture was not correct). The employee went to see what was wrong. The employee saw the product falling to the ground due to the drain discharge valve being open. The employee closed the drain valve with his foot. In doing so, the line 8 blending system pipeline did not have an open free flow path, the valve above the magnet was closed and not open to the destination. When the discharge drain valve was closed, the positive displacement pump developed high pressure in the pipeline and blew out the line magnet. The employee was hit in the abdomen which tore his intestine. The employee was hospitalized for these injuries.

Keywords: Abdomen, Drain Pipe, High Pressure, High Pressure Pipe, Magnet, Struck By

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1454056.015 54 M Hospitalized injury Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.