Inspection Detail
Inspection: 1451854.015 - Climax Molybdenum Company
Inspection Information - Office: Iowa 0751910
Site Address:
Climax Molybdenum Company
2598 Hwy 61
Fort Madison, IA 52627
Mailing Address:
2598 Hwy 61, Fort Madison, IA 52627
Union Status: NonUnion
SIC:
NAICS: 331410
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 01/30/2020
Emphasis:
Case Closed: 03/03/2020
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1526276 | Yes |
Investigation Summary
At 6:35 p.m. on December 11, 2019, an employee was removing bolts around a railcar hatch. A rapid release of hydrogen sulfide gas from the railcar somehow entered the employee's respirator mask. The employee suffered respiratory irritation or arrest brought on by acute exposure to hydrogen sulfide gas. The employee was hospitalized overnight and then released with no work restrictions.
Keywords: Bolt, Chemical Exposure, Chemical Vapor, Flatbed Rail Car, Hydrogen Sulfide, Removing, Respirator, Respiratory
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1451854.015 | 62 | M | Hospitalized injury |