Inspection Detail
Inspection: 1451233.015 - Rea Magnet Wire Company, Inc.
Inspection Information - Office: Bridgeport Area Office
Site Address:
Rea Magnet Wire Company, Inc.
129 Soundview Road
Guilford, CT 06437
Mailing Address:
129 Soundview Road, Guilford, CT 06437
Union Status: Union
SIC:
NAICS: 331222/Steel Wire Drawing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/16/2019
Emphasis:
Case Closed: 03/23/2021
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1521602 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 2 | 3 | |||
Current Violations | 1 | 2 | 3 | |||
Initial Penalty | $0 | $0 | $52,096 | $6,000 | $0 | $58,096 |
Current Penalty | $0 | $0 | $30,000 | $3,500 | $0 | $33,500 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Repeat | 19100212 A01 | 01/09/2020 | 03/15/2020 | $30,000 | $52,096 | $0 | I - Informal Settlement | ||
2. | 02001 | Other | 19040029 B01 | 01/09/2020 | $0 | $1,000 | $0 | I - Informal Settlement | |||
3. | 02002 | Other | 19040039 A02 | 01/09/2020 | $3,500 | $5,000 | $0 | I - Informal Settlement |
Investigation Summary
At 8:13 a.m. on October 1, 2019, an employee was adding copper wire to and empty spool without using pliers to pull the wire. The employee was hospitalized to treat a partial left index finger amputation.
Keywords: Amputated, Finger, Metal Wire, Partial Amputation, Pulling
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1451233.015 | 65 | M | Hospitalized injury | Milling and planing machine operators |