Inspection Detail
Inspection: 1451074.015 - Skyline Well Testing
Inspection Information - Office: Denver Area Office
Site Address:
Skyline Well Testing
Wcr 90 & Wcr 36
Pierce, CO 80650
Mailing Address:
11321 Cr 72, Severance, CO 80615
Union Status: NonUnion
SIC:
NAICS: 213112/Support Activities for Oil and Gas Operations
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/13/2019
Emphasis: L:Oilgas
Case Closed: 02/27/2020
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1526317 | Yes | |
| Inspection | 1451453 | Yes | |
| Inspection | 1451467 | Yes |
Investigation Summary
At 9:00 p.m. on December 12, 2019, an employee was doing a checklist with a coworker. The employee heard a noise and got onto the empty flowback tank to investigate. The employee told the coworker to close the valve on the other tank. The tank the employee was on exploded, propelling him approximately 30 feet to the ground. The employee was hospitalized to treat the following: lacerated spleen, assorted contusions and lacerations, and a broken pelvis.
Keywords: Broken Bone, Contusion, Ejected, Explosion, Fall, Fall From Elevation, Laceration, Noise, Pelvis, Shut-Off Valve, Spleen
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1451074.015 | 45 | M | Hospitalized injury |
Translate