Inspection Detail
Inspection: 1450919.015 - Big 4 Trucking, Inc.
Inspection Information - Office: Baton Rouge Area Office
Site Address:
Big 4 Trucking, Inc.
63399 Hwy 51 N
Roseland, LA 70456
Mailing Address:
63399 Hwy 51 N, Roseland, LA 70456
Union Status: NonUnion
SIC:
NAICS: 484121/ General Freight Trucking, Long-Distance, Truckload
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/12/2019
Emphasis:
Case Closed: 07/24/2020
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1524162 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $8,096 | $0 | $0 | $0 | $0 | $8,096 |
Current Penalty | $4,858 | $0 | $0 | $0 | $0 | $4,858 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100178 L03 I J | 03/10/2020 | 03/23/2020 | $4,858 | $8,096 | $0 | I - Informal Settlement |
Investigation Summary
At 4:45 p.m. on November 4, 2019, two employees were troubleshooting the failure to idle of a forklift. An employee secured an LP propane bottle to commence troubleshooting of the fuel system. A filter clog created a back pressure that blew a line and gas collected in the hood area. The mechanic started the forklift, and the distributor ignited the propane, causing a flash fire. The two employees were hospitalized to treat second degree burns.
Keywords: Burn, Clogged, Fire, Flash, Forklift, Fuel Tank, Gas, Ignite, Ignition, Propane, Troubleshooting
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1450919.015 | 32 | M | Hospitalized injury | ||
2 | 1450919.015 | 32 | M | Hospitalized injury |