Inspection Detail
Inspection: 1449910.015 - Cep Bio-Coat Llc Dba Orchid Orthopedic Solutions
Inspection Information - Office: Miosha General Industry Safety & Health Division
Site Address:
Cep Bio-Coat Llc Dba Orchid Orthopedic Solutions
23149 Commerce Dr
Farmington Hills, MI 48335
Mailing Address:
23149 Commerce Dr, Farmington Hills, MI 48335
Union Status: NonUnion
SIC:
NAICS: 339112/Surgical and Medical Instrument Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 12/19/2019
Emphasis: N:Amputate
Case Closed: 02/21/2020
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1519481 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $6,300 | $0 | $0 | $0 | $0 | $6,300 |
| Current Penalty | $3,150 | $0 | $0 | $0 | $0 | $3,150 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 408.1011(A) | 01/27/2020 | 02/28/2020 | $3,150 | $6,300 | $0 | I - Informal Settlement | ||
| 2. | 01001B | Serious | 19100147 C07 I A | 01/27/2020 | 02/28/2020 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
At 8:30 p.m. on November 14, 2019, an employee was working for a firm that made medical and surgical instruments. She supervised mechanics and repair technicians. She was working in the facility's HA department, where the HA1 and HA2 robotic work cells were located. She was changing out a plasma spray gun from the HA2 robot. The robot was still energized. It had not been locked out. As she was loosening a bolt to detach the plasma spray gun from the robot, the wrench she was using contacted a metal fitting on the spray gun water line. An arc flash ensued. The employee received second-degree burns on two fingers on her left hand and on her right wrist. She was treated without hospitalization. The employee had not been trained on lockout or the use of padlocks. The interlocked access doors to the cell were equipped with a limit switch that did not deenergize the robot or the spray gun. The employee entered the cell two to three times daily. A risk assessment had not been performed. The employer was not enforcing energy control procedures.
Keywords: Burn, Electric Arc, Electric Arc Flash, Energized, Flash, Hand Tool, Inadequate Maint, Interlock, Lockout, Lockout/Tagout, Maintenance, Robot, Skin, Training, Wrench
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1449910.015 | 44 | F | Non Hospitalized injury | Supervisors, mechanics and repairers |
Translate