Inspection Detail
Inspection: 1449701.015 - Arcelormittal Cleveland, Llc
Inspection Information - Office: Cleveland Area Office
Site Address:
Arcelormittal Cleveland, Llc
2234 Main Avenue Sw
Warren, OH 44481
Mailing Address:
3060 Eggers Avenue, Cleveland, OH 44105
Union Status: Union
SIC:
NAICS: 331110
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 05/07/2020
Emphasis:
Case Closed: 06/25/2020
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1523549 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 1 | 1 | ||||
Current Violations | 1 | 1 | ||||
Initial Penalty | $12,145 | $0 | $0 | $0 | $0 | $12,145 |
Current Penalty | $8,501 | $0 | $0 | $0 | $0 | $8,501 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001A | Serious | 5A0001 | 05/14/2020 | $8,501 | $12,145 | $0 | I - Informal Settlement | |||
2. | 01001B | Serious | 19100147 D | 05/14/2020 | $0 | $0 | $0 | I - Informal Settlement | Citation has been deleted. |
Investigation Summary
At 2:00 p.m. on December 3, 2019, two employees were preparing to break a flange on a pipe containing coke oven gas in order to install a blank. A water seal valve was broken due to the water line being inadvertently bumped close, causing the water seal to break. The employees were exposed to carbon monoxide in coke oven gas, and were hospitalized.
Keywords: Carbon Monoxide, Coke Oven, Flange, Gas
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1449701.015 | 57 | M | Non Hospitalized injury | ||
2 | 1449701.015 | 46 | F | Hospitalized injury |