Inspection Detail
Inspection: 1448230.015 - Jbl Industrial Services, Inc.
Inspection Information - Office: Tampa Area Office
Site Address:
Jbl Industrial Services, Inc.
3193 Ne 366th Trail
Okeechobee, FL 34972
Mailing Address:
8455 E. Center St., Okeechobee, FL 34974
Union Status: NonUnion
SIC:
NAICS: 238220/ Plumbing, Heating, and Air-Conditioning Contractors
Inspection Type: Referral
Scope: Partial
Advanced Notice: Y
Ownership: Private
Safety/Health: Safety
Close Conference: 12/23/2019
Emphasis: N:Amputate
Case Closed: 02/11/2020
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1521721 | Yes | |
| Inspection | 1448837 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $3,978 | $0 | $0 | $0 | $0 | $3,978 |
| Current Penalty | $3,978 | $0 | $0 | $0 | $0 | $3,978 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19260021 B02 | 01/08/2020 | $3,978 | $3,978 | $0 | Z - Issued |
Investigation Summary
At 5:45 p.m. on November 25, 2019, an employee was working for a plumbing, heating, and air conditioning contractor. He was a concrete and terrazzo finisher. He was cleaning the paddles of a concrete mixer by pouring water into it from a 5-gallon (18.9-liter) bucket. The mixer was attached to a Kubota Model SVL 95-2S track loader, with serial number 427072J01820. The mixer was used regularly or almost every day, and all employees cleaned it. The employee's left foot was resting on the mixer's discharge port gate. The gate's opening was 6 in. wide, 6 in. long, and about 3 in. deep (150 mm wide, 150 mm long, and about 75 mm deep). As the employee was dumping the last bucket of water into the mixer, his foot slid into the port. His foot became caught in the mixer paddles, and all five toes of his left foot were amputated. He was hospitalized. During an inspection, it was learned that employees were taught by both the firm's owner and the firm's lead trainer to clean the mixer with the exhaust gate open. Doing so allowed dirty water to drain from the mixer as clean water was poured in, despite the hazards associated with cleaning the mixer while the port is open. The firm's owner, in an interview, said that he had been cleaning the mixer that way since he acquired it and that he never told the employees not to put any part of their bodies in the open gate port while the mixer was running.
Keywords: Amputated, Amputation, Caught Between, Caught By, Caught In, Cleaning, Concrete Mixer, Construction, Foot, Instantaneous amputation, Lockout, Lockout/Tagout, Mixer, Mixer Blade, Rotating Parts, Toe, Training, Traumatic Amputation
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1448230.015 | 29 | M | Hospitalized injury | Concrete and terrazzo finishers |