Inspection Detail
Inspection: 1446715.015 - Vibracoustic Usa Inc
Inspection Information - Office: Fairview Heights Area Office
Site Address:
Vibracoustic Usa Inc
102 Industrial Ave
Carmi, IL 62821
Mailing Address:
102 Industrial Ave, Carmi, IL 62821
Union Status: NonUnion
SIC:
NAICS: 339991/ Gasket, Packing, and Sealing Device Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 01/22/2020
Emphasis: N:Amputate
Case Closed: 06/15/2020
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1518832 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 2 | 1 | 3 | |||
| Current Violations | 1 | 1 | 2 | |||
| Initial Penalty | $15,422 | $0 | $0 | $0 | $0 | $15,422 |
| Current Penalty | $7,711 | $0 | $0 | $0 | $0 | $7,711 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001A | Serious | 19100132 A | 02/21/2020 | 04/08/2020 | $7,711 | $7,711 | $0 | I - Informal Settlement | ||
| 2. | 01001B | Serious | 19100212 A01 | 02/21/2020 | 06/03/2020 | $0 | $7,711 | $0 | I - Informal Settlement | ||
| 3. | 02001 | Other | 19040039 A02 | 02/21/2020 | $0 | $0 | $0 | I - Informal Settlement |
Investigation Summary
At 11:00 a.m. on October 22, 2019, an employee working for a parts manufacturer was operating a Jing Day Model Number JD-H600 Hydraulic Molding Machine. The employee needed to remove finished parts from the machine before installing new stock to be compressed but one part became stuck. The employee opened the clam shell type mold with the use of a chain hoist which was located above the mold. The employee reached into the open mold to retrieve a stuck part. As the employee reached into the machine, the hook disengaged from the handle causing the plate to fall on the employee's arms. The employer provided a safety bar to hold the mold in a open position. The employee would have to manually place the safety bar in to position before removing parts from the machine but did not do this. The mold was estimated to be between 150 and 200 degrees Fahrenheit. The employee had been working alone at the work station, but three coworkers were working nearby at other work stations. The employee incurred burns to his upper hands and was hospitalized.
Keywords: Burn, Crane, Crane Hook, Falling Object, Hand, High Temperature, Hoisting Mechanism, Hydraulic, Lack of Work Procedures, Machine Guarding, Machine operator, Molding Machine, PPE, PPE Hazard Assessment, Pinched, Struck By, Stuck
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1446715.015 | 21 | M | Hospitalized injury | Machine operators, not specified |