Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1445228.015 - Innovative Ag Services

Inspection Information - Office: Iowa 0751910

 

Inspection Nr: 1445228.015
Report ID: 0751910
Date Opened: 11/15/2019

Site Address:
Innovative Ag Services
402 High St
Elkader, IA 52043

Mailing Address:
402 High St, Elkader, IA 52043

Union Status: NonUnion

SIC:

NAICS: 424910/Farm Supplies Merchant Wholesalers


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/15/2019

Emphasis:

Case Closed: 03/03/2020


Related Activity
Type Activity Nr Safety Health
Referral 1517043 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 4 4
Initial Penalty $30,402 $0 $0 $0 $0 $30,402
Current Penalty $22,728 $0 $0 $0 $0 $22,728
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100134 C02 I 12/30/2019 01/06/2020 $5,682 $5,682 $0 I - Informal Settlement  
2. 01002 Serious 19100146 C04 12/30/2019 01/27/2020 $5,682 $11,934 $0 I - Informal Settlement  
3. 01003 Serious 19100219 H01 12/30/2019 01/06/2020 $5,682 $5,682 $0 I - Informal Settlement  
4. 01004A Serious 19100272 D 12/30/2019 01/27/2020 $5,682 $7,104 $0 I - Informal Settlement  
5. 01004B Serious 19100272 M04 12/30/2019 01/27/2020 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 121727.015
Event: 11/09/2019
Employee inhales smoke when preparing to enter dryer after f

At 5:30 p.m. on November 9, 2019, an employee working for a wholesale farm merchant was operating a grain dryer. When he obtained a sample of corn to be tested for moisture content, he smelled something burning from the bottom of the dryer. The employee extracted discovered burning cardboard at the bottom of the dryer so he pulled it out of the machine. He then shut down the dryer and shut off the electrical and gas. The dryer is a confined space and he determined it was safe to enter. The employee opened the two manhole covers in the floor. When the second lid was removed, smoke billowed out into his face causing him to breathe in the smoke. The employee experienced respiratory irritation due to smoke inhalation and was hospitalized.

Keywords: Agriculture, Agriculture Machinery/Vehicle, Confined Space, Dryer, Face, Fire, Inhalation, Insufficient Supervision, Lung, Manhole, Manhole Cover, Material Handling, Respiratory, Respiratory Tract, Smoke, Smoke Inhalation

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1445228.015 29 M Hospitalized injury
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close