Inspection Detail
Inspection: 1442261.015 - Clarios, Llc
Inspection Information - Office: Wilmington Area Office
Site Address:
Clarios, Llc
700 N Broad St
Middletown, DE 19709
Mailing Address:
750 Patriot Drive 700 N Broad Street, Middletown, DE 19709
Union Status: Union
SIC:
NAICS: 335912/Primary Battery Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 11/12/2019
Emphasis: N:Amputate
Case Closed: 06/02/2020
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1514733 | Yes |
Investigation Summary
At 9:45 a.m. on November 2, 2019, an employee, a supervisor, was kneeling down looking under an electrofusion welding machine for a bracket that had broken off. The employee lost his balance and his left hand slipped off the frame of the machine and his left index finger was caught between a table transfer cylinder and the metal stop. Employee suffered a fingertip amputation to his left index finger and was treated without hospitalization.
Keywords: Amputated, Amputation, Automatic Machine, Caught Between, Cylinder, Fingertip, Frame, Lost Balance, Metal, Slip, Welding
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1442261.015 | 58 | M | Non Hospitalized injury | Mechanical controls and valve repairers |