Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1439439.015 - Iowa Precision Forge

Inspection Information - Office: Iowa 0751910

 

Inspection Nr: 1439439.015
Report ID: 0751910
Date Opened: 10/22/2019

Site Address:
Iowa Precision Forge
510 S Howell St
Davenport, IA 52802

Mailing Address:
510 S Howell St, Davenport, IA 52802

Union Status: NonUnion

SIC:

NAICS: 332111/Iron and Steel Forging


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/22/2019

Emphasis: N:Amputate, S:Amputate

Case Closed: 02/27/2020


Related Activity
Type Activity Nr Safety Health
Referral 1509489 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $5,303 $0 $0 $0 $0 $5,303
Current Penalty $3,500 $0 $0 $0 $0 $3,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100218 A02 III 12/02/2019 01/21/2020 $1,500 $2,273 $0 I - Informal Settlement  
2. 01002 Serious 19100219 C02 I 12/02/2019 01/21/2020 $1,000 $1,515 $0 I - Informal Settlement  
3. 01003A Serious 19100305 G01 IV A 12/02/2019 01/21/2020 $1,000 $1,515 $0 I - Informal Settlement  
4. 01003B Serious 19100334 A02 I 12/02/2019 01/21/2020 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 120946.015
Event: 10/15/2019
Employee amputates finger between heat shield and bar rest

At 2:30 p.m. on October 15, 2019, an employee was attempting to reposition a 34.5 inch by 96 inch 836 grade steel heat shield on a shop-made furnace. The heat shield was attached to a set of brackets attached to a gas powered furnace. When the employee pulled the shield forward, the part slipped off of the brackets and fell. The employee caught his left index finger in between the falling heat shield and the 2-inch diameter bar rest. The employee amputated his finger above the second knuckle and was hospitalized.

Keywords: Amputated, Amputation, Caught Between, Clamp, Crushed, Falling Object, Finger, Furnace, Instantaneous amputation, Iron, Iron Worker, Lack of Work Procedures, Material Handling, Metal, Misjudgment, Misjudgment of Hazardous Situation, Partial Amputation, Pinch Point, Pinched, Steel, Traumatic Amputation

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1439439.015 61 M Hospitalized injury Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.