Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1438703.015 - Bfp Fire Protection, Inc.

Inspection Information - Office: Fremont District Office

 

Inspection Nr: 1438703.015
Report ID: 0950612
Date Opened: 10/18/2019

Site Address:
Bfp Fire Protection, Inc.
1170 Coleman Ave.
San Jose, CA 95110

Mailing Address:
17 Janis Way, Scotts Valley, CA 95066

Union Status: Union

SIC:

NAICS: 238220/ Plumbing, Heating, and Air-Conditioning Contractors


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 01/16/2020

Emphasis:

Case Closed: 07/15/2020


Related Activity
Type Activity Nr Safety Health
Accident 1508792
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $0 $0 $0 $2,250 $0 $2,250
Current Penalty $0 $0 $0 $1,800 $0 $1,800
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3314(D) 01/21/2020 $600 $750 $0 02/05/2020 O - Administrative Law Judge Order  
2. 01002 Other 3314(L) 01/21/2020 $600 $750 $0 02/05/2020 O - Administrative Law Judge Order  
3. 01003 Other 3400(F) 01/21/2020 $600 $750 $0 02/05/2020 O - Administrative Law Judge Order  

Investigation Summary

Investigation Nr: 120933.015
Event: 10/14/2019
Employee amputates finger when caught in pipe threading mach

At 7:00 a.m. on October 14, 2019, an employee working as a pipelayer for a fire protection service was setting up a groover attachment unit on a pipe threading machine. The employee inadvertently stepped on the foot control which caused the machine to power on while his right hand was in the danger zone. The employee caught his index finger between the machine's carriage bar and the groover nipple attachment. A coworker transported the employee to the hospital. The employee amputated his finger to the first joint and was hospitalized.

Keywords: Amputated, Amputation, Caught Between, Finger, Fire Ext System, Foot Control, Hand, Installing, Instantaneous amputation, Lockout, Lockout/Tagout, Machine operator, Metal Pipe, Partial Amputation, Pinch Point, Pinched, Pipe, Point Of Operation, Threading Machine, Traumatic Amputation

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1438703.015 50 M Hospitalized injury Pipelayer
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close