Inspection Detail
Inspection: 1437166.015 - Engineered Glass Products, L.L.C.
Inspection Information - Office: Chicago South Area Office
Site Address:
Engineered Glass Products, L.L.C.
2857 South Halsted St.
Chicago, IL 60608
Mailing Address:
2857 South Halsted St., Chicago, IL 60608
Union Status: NonUnion
SIC:
NAICS: 327215/Glass Product Manufacturing Made of Purchased Glass
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/09/2019
Emphasis: N:Amputate
Case Closed: 03/02/2020
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1506184 | Yes |
Investigation Summary
At 7:00 a.m. on October 3, 2019, an employee was working for a firm that manufactured glass products from glass that it had purchased. He operated a fabricating machine. He was working inside a heat exchanger to cut out old pipes that were going to be replaced with new ones. He was using a portable handheld grinder to cut the pipes out. As he went to cut out another piece of pipe, he lost his footing. The grinder struck the employee's upper left arm in the bicep. He suffered a laceration. He was hospitalized.
Keywords: Arm, Cutting, Grinder, Heat Exchanger, Laceration, Machine operator, Metal Pipe, Pipe, Portable Power Tool, Tripped
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1437166.015 | 40 | M | Hospitalized injury | Fabricating machine operators, n.e.c. |