Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1437121.015 - Stevens Towing Co.,Inc.

Inspection Information - Office: Raleigh Area Office

 

Inspection Nr: 1437121.015
Report ID: 0420300
Date Opened: 10/09/2019

Site Address:
Stevens Towing Co.,Inc.
4170 Highway 165
Yonges Island, SC 29449

Mailing Address:
4170 Highway 165, Yonges Island, SC 29449

Union Status: NonUnion

SIC:

NAICS: 336611/Ship Building and Repairing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/10/2019

Emphasis: L:Maritime

Case Closed: 03/23/2020


Related Activity
Type Activity Nr Safety Health
Referral 1507848 Yes
Inspection 1464969 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 2 3
Current Violations 1 2 3
Initial Penalty $10,409 $0 $0 $8,674 $0 $19,083
Current Penalty $6,245 $0 $0 $5,204 $0 $11,450
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19150152 A 02/25/2020 03/06/2020 $6,245 $10,409 $0 I - Informal Settlement  
2. 01001B Serious 19150152 B 02/25/2020 03/06/2020 $0 $0 $0 I - Informal Settlement  
3. 02001 Other 19040039 A02 02/25/2020 $5,204 $8,674 $0 I - Informal Settlement  
4. 02002 Other 19150055 G03 02/25/2020 03/06/2020 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 120634.015
Event: 10/04/2019
Employee burns abdomen when hose fails on gas torch

At 9:30 a.m. on October 4, 2019, an employee was in the process of heating a piece of angel iron on the inner hull of a barge with a gas torch (oxygen and propylene). The torch was lit at the time of the incident. While starting to heat the angel iron the oxygen hose began to rapidly expand causing a large growing bubble within a few inches of the torch. The hose burst and oxygen contacted the red-hot angle iron which caused a small explosion. The employee yelled for a coworker turn off the gas while he bent the hose to prevent more oxygen from escaping. Due to the small explosion and the employee wearing a polyester (or similar man-made fiber) shirt and jacket, the shirt melted on hid lower abdomen. The employee was burned and required hospitalization and a skin graft.

Keywords: Abdomen, Burn, Defect, Defective, Defective Equipment, Explosion, Fire, Gas Leak, High Pressure, High Temperature, Hose, Insufficient Supervision, Oxygen, PPE, PPE Hazard Assessment, Propane Torch, Propylene, Protective Clothing

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1437121.015 28 M Hospitalized injury
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close