Inspection Detail
Inspection: 1436792.015 - Dupont Teijin Films U.S. Lp
Inspection Information - Office: Va-E-Richmond (Regional Office) - Health 0355121
Site Address:
Dupont Teijin Films U.S. Lp
5401 Jefferson Davis Highway
Richmond, VA 23234
Mailing Address:
P.O. Box 27222, Richmond, VA 23261
Union Status: Union
SIC:
NAICS: 326130/ Laminated Plastics Plate, Sheet (except Packaging), and Shape Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 12/04/2019
Emphasis:
Case Closed: 01/21/2020
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1506129 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 3 | 3 | ||||
| Current Violations | 2 | 2 | ||||
| Initial Penalty | $16,455 | $0 | $0 | $0 | $0 | $16,455 |
| Current Penalty | $10,038 | $0 | $0 | $0 | $0 | $10,038 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100106 H07 I A | 12/06/2019 | $3,346 | $5,485 | $0 | I - Informal Settlement | |||
| 2. | 01004A | Serious | 19100133 A01 | 12/06/2019 | $3,346 | $5,485 | $0 | I - Informal Settlement | |||
| 3. | 01004B | Serious | 19100138 B | 12/06/2019 | $3,346 | $5,485 | $0 | I - Informal Settlement |
Investigation Summary
At 7:00 a.m. on October 6, 2019, an employee was clearing a vacuum roll wrap from a vacuum dryer by manually pulling solvent-soaked film from the dryer and placing it in a pile. While clearing the vacuum wrap, the pile of film ignited, causing a flash fire which travelled to the employee. The employee was wearing Nomex coveralls, safety glasses, static-dissipating safety boots, and Kevlar cut-resistant gloves. All equipment and machinery was bonded and grounded. The employee was hospitalized to treat third degree burns to both wrists, the right side of their face, and right ear.
Keywords: Burn, Cleaning, Dryer, Ear, Eye protection, Face, Fire, Glove, Ignite, PPE, Wrist
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1436792.015 | 56 | M | Hospitalized injury | Chemical technicians |