Inspection Detail
Inspection: 1436256.015 - American Cooling Tower
Inspection Information - Office: Santa Ana District Office
Site Address:
American Cooling Tower
3130 W Harvard St
Santa Ana, CA 92704
Mailing Address:
3130 W Harvard St, Santa Ana, CA 92704
Union Status: NonUnion
SIC:
NAICS: 333415/Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
Inspection Type: Accident
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/26/2020
Emphasis:
Case Closed: 02/26/2020
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Accident | 1497957 |
Investigation Summary
At 10:30 a.m. on August 26, 2019, an employee was pressure testing a heat exchanger, when the flange failed and exploded. The employee was hospitalized to treat a laceration and fracture to the left forearm.
Keywords: Arm, Explosion, Flange, Forearm, Fracture, Heat Exchanger, Laceration, Pressure
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1436256.015 | 58 | M | Hospitalized injury | Mechanical controls and valve repairers |