Inspection Detail
Inspection: 1435837.015 - Joon, Llc
Inspection Information - Office: Mobile Area Office
Site Address:
Joon, Llc
1500 County Rd 177
Cusseta, AL 36852
Mailing Address:
1500 County Rd 177, Cusseta, AL 36852
Union Status: NonUnion
SIC:
NAICS: 336370/Motor Vehicle Metal Stamping
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/03/2019
Emphasis: N:Amputate, L:Autosup
Case Closed: 12/31/2019
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1504151 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $13,260 | $0 | $0 | $0 | $0 | $13,260 |
| Current Penalty | $13,260 | $0 | $0 | $0 | $0 | $13,260 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100147 C04 I | 12/02/2019 | 12/10/2019 | $13,260 | $13,260 | $0 | Z - Issued |
Investigation Summary
At 1:00 p.m. on September 30, 2019, an employee was troubleshooting a robotic cell at a motor vehicle metal stamping facility. The robotic cell performed cold welds, and the employee attempted to access the alignment of the welding tips. When the employee activated a pneumatic solenoid, his index finger was caught between the welding tips. The employee sustained a partial fingertip amputation and was hospitalized.
Keywords: Amputated, Amputation, Energized, Finger, Fingertip, Motor Vehicle, Pneumatic, Pneumatic equipment, Robot, Robotics, Troubleshooting, Welding
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1435837.015 | 29 | M | Hospitalized injury | Machinery maintenance occupations |
Translate