Inspection Detail
Inspection: 1434840.015 - Gryphon Technologies
Inspection Information - Office: Norfolk Area Office
Site Address:
Gryphon Technologies
4600 Village Avenue
Norfolk, VA 23502
Mailing Address:
4600 Village Avenue, Norfolk, VA 23502
Union Status: NonUnion
SIC:
NAICS: 336611/Ship Building and Repairing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 02/12/2020
Emphasis:
Case Closed: 04/22/2020
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1504408 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 6 | 6 | ||||
Current Violations | 1 | 3 | 4 | |||
Initial Penalty | $69,398 | $0 | $0 | $0 | $0 | $69,398 |
Current Penalty | $8,771 | $0 | $0 | $19,759 | $0 | $28,530 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Other | 19100106 E02 III | 02/19/2020 | 03/16/2020 | $6,747 | $13,494 | $0 | I - Informal Settlement | ||
2. | 01002 | Serious | 19100106 E06 I | 02/19/2020 | 03/16/2020 | $8,771 | $13,494 | $0 | I - Informal Settlement | ||
3. | 01003 | Other | 19100106 E06 II | 02/19/2020 | 03/16/2020 | $6,265 | $9,639 | $0 | I - Informal Settlement | ||
4. | 01004 | Serious | 19100178 O01 | 02/19/2020 | 03/16/2020 | $0 | $11,566 | $0 | I - Informal Settlement | Citation has been deleted. | |
5. | 01005 | Serious | 19150077 C | 02/19/2020 | 03/16/2020 | $0 | $7,711 | $0 | I - Informal Settlement | Citation has been deleted. | |
6. | 01006 | Other | 19150152 B | 02/19/2020 | 03/16/2020 | $6,747 | $13,494 | $0 | I - Informal Settlement |
Investigation Summary
At 9:30 a.m. on September 25, 2019, an employee was refueling a small boat when he went to check the battery connections on the electric pump. A spark caused the gasoline vapors to flash striking the employee. The employee received second and third degree burns to his arm and head and required hospitalization.
Keywords: Arm, Battery, Boat, Burn, Chemical Vapor, Electric Pump, Fire, Flammable Liquid, Flammable Vapors, Flash, Gasoline, Head, High Temperature, Ignite, Insufficient Supervision, Lack of Engineering Controls, Lack of Work Procedures, Misjudgment, Misjudgment of Hazardous Situation, Shipyard, Spark, Struck By
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1434840.015 | 36 | M | Hospitalized injury | Technicians, n.e.c. |