Inspection Detail
Inspection: 1430556.015 - Jammies Environmental Inc.
Inspection Information - Office: Boise Area Office
Site Address:
Jammies Environmental Inc.
803 Mill Rd
Lewiston, ID 83501
Mailing Address:
128 Industrial Way, Longview, WA 98632
Union Status: NonUnion
SIC:
NAICS: 562998/All Other Miscellaneous Waste Management Services
Inspection Type: Fat/Cat
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 09/11/2019
Emphasis:
Case Closed: 11/20/2019
Type | Activity Nr | Safety | Health |
---|---|---|---|
Accident | 1496648 |
Investigation Summary
At 1:00 p.m. on September 9, 2019, an employee was exiting a confined space and complained of chest cramps. The employee suffered a heart attack from an existing heart condition and died.
Keywords: Cardiac Arrest, Chest, Chest pain, Confined Space, Heart, Heart Attack
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1430556.015 | 41 | M | Fatality | Laborers, except construction |