Inspection Detail
Inspection: 1430275.015 - Eec Geneva, Llc
Inspection Information - Office: Cleveland Area Office
Site Address:
Eec Geneva, Llc
3120 Market Place Drive Suite E
Ashtabula, OH 44004
Mailing Address:
3120 Market Place Drive Suite E, Ashtabula, OH 44004
Union Status: NonUnion
SIC:
NAICS: 561320/Temporary Help Services
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Health
Close Conference: 09/12/2019
Emphasis:
Case Closed: 11/25/2019
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1492688 | Yes | Yes |
Inspection | 1428746 | Yes |
Investigation Summary
At 1:00 p.m. on August 24, 2019, Employee # 1 was using compressed air to put out a fire caused by molten aluminum that fell onto hydraulic oil that leaked from the tilter oil fittings. He went to the hospital Monday morning at 4:30 a.m. and was admitted to treat breathing difficulties. He suffered smoking inhalation and chemical pneumonitis.
Keywords: Chemical, Compressed Air, Fire, Hydraulic, Molten Metal, Smoke Inhalation
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1430275.015 | 52 | M | Hospitalized injury | Operating engineers |