Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1429425.015 - Katoen Natie Gulf Coast, Inc.

Inspection Information - Office: Houston South Area Office

 

Inspection Nr: 1429425.015
Report ID: 0626700
Date Opened: 09/09/2019

Site Address:
Katoen Natie Gulf Coast, Inc.
10925 Sh 225 Rail Transfer Area
La Porte, TX 77571

Mailing Address:
10925 Sh 225, La Porte, TX 77571

Union Status: NonUnion

SIC:

NAICS: 488991/Packing and Crating


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 09/09/2019

Emphasis:

Case Closed: 03/03/2021


Related Activity
Type Activity Nr Safety Health
Referral 1494059 Yes
Inspection 1430587 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 1 1
Initial Penalty $53,040 $0 $0 $0 $0 $53,040
Current Penalty $26,520 $0 $0 $0 $0 $26,520
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100212 A01 11/04/2019 01/03/2020 $26,520 $13,260 $0 I - Informal Settlement  
2. 01002 Serious 19100147 C04 II C 11/04/2019 12/09/2019 $0 $13,260 $0 I - Informal Settlement Citation has been deleted.
3. 01003 Serious 19100147 C04 II D 11/04/2019 12/09/2019 $0 $13,260 $0 I - Informal Settlement Citation has been deleted.
4. 01004 Serious 19100147 C07 I A 11/04/2019 12/09/2019 $0 $13,260 $0 I - Informal Settlement Citation has been deleted.

Investigation Summary

Investigation Nr: 119670.015
Event: 08/31/2019
Employee amputates fingers in automatic pneumatic valve

At 3:12 p.m. on August 31, 2019, an employee, a temporary agency worker, was washing flexible metallic hoses and associated piping used in unloading of high density polyethylene cargo from a rail hopper car. This normally involves four transfer hoses that are connected to transfer piping. In this case, two transfer hoses had been removed from the system, leaving conducting transfers and washing of the system with only two hoses. The employee was using a water hose and spraying up inside the fixed piping with the vacuum system running to wash the piping on a connection that had no transfer hose attached. An automatic closing pneumatic gate valve activated and closed on the employee's hand inside the piping. The employee was hospitalized to treat amputations of all five fingers of his left hand.

Keywords: Activated, Amputated, Amputation, Caught In, Cleaning, Closed, Finger, Gate, Hopper Car, Hose, Pipe, Pneumatic, Temporary Worker, Valve

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1429425.015 21 M Hospitalized injury Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.