Inspection Detail
Inspection: 1426848.015 - Ahf Products
Inspection Information - Office: Charleston Area Office
Site Address:
Ahf Products
259 Armstrong Dr
Beverly, WV 26253
Mailing Address:
259 Armstrong Dr, Beverly, WV 26253
Union Status: NonUnion
SIC:
NAICS: 321918/Other Millwork (including Flooring)
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 08/20/2019
Emphasis:
Case Closed: 05/22/2020
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1489623 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 4 | 4 | ||||
Current Violations | 3 | 3 | ||||
Initial Penalty | $42,411 | $0 | $0 | $0 | $0 | $42,411 |
Current Penalty | $27,855 | $0 | $0 | $0 | $0 | $27,855 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100022 B | 02/10/2020 | 03/16/2020 | $11,469 | $13,494 | $0 | I - Informal Settlement | ||
2. | 01002 | Serious | 19100028 B01 I | 02/10/2020 | 03/16/2020 | $8,193 | $9,639 | $0 | I - Informal Settlement | ||
3. | 01003A | Serious | 19100252 A01 I | 02/10/2020 | 03/06/2020 | $8,193 | $9,639 | $0 | I - Informal Settlement | ||
4. | 01003B | Serious | 19100252 A01 II | 02/10/2020 | 03/06/2020 | $0 | $0 | $0 | I - Informal Settlement | Citation has been deleted. | |
5. | 01003C | Serious | 19100252 A02 III A 3 | 02/10/2020 | 03/06/2020 | $0 | $0 | $0 | I - Informal Settlement | ||
6. | 01004A | Serious | 19100252 A02 III A 1 | 02/10/2020 | 03/06/2020 | $0 | $9,639 | $0 | I - Informal Settlement | Citation has been deleted. |
Investigation Summary
At 10:45 a.m. on August 19, 2019, two employees were repairing a leak on a steam line located in the ceiling of a pre-dryer/kiln. The employees were standing on the sheet-metal ceiling of the pre-dryer/kiln, when the sheet metal ceiling collapsed under the weight of the employees. One employee fell to the concrete floor. The other employee fell onto a welding cart. One employee sustained fractures to the leg; the other, impalement due to a hook on the welding cart. One employee was hospitalized; the other was not hospitalized.
Keywords: Ceiling, Ceiling Panel, Fall, Fall From Elevation, Fracture, Impaled, Kiln, Leg, Sheet Metal, Suspended Ceiling
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1426848.015 | 40 | M | Non Hospitalized injury | Mechanical engineering technicians | |
2 | 1426848.015 | 46 | M | Hospitalized injury | Mechanical engineering technicians |