Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1425620.015 - Cp Manufacturing, Inc.

Inspection Information - Office: San Diego District Office

 

Inspection Nr: 1425620.015
Report ID: 0950632
Date Opened: 08/23/2019

Site Address:
Cp Manufacturing, Inc.
6795 Calle De Linea
San Diego, CA 92154

Mailing Address:
6795 Calle De Linea, San Diego, CA 92154

Union Status: NonUnion

SIC:

NAICS: 332322/Sheet Metal Work Manufacturing


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 12/09/2019

Emphasis: N:Amputate

Case Closed: 07/11/2022


Related Activity
Type Activity Nr Safety Health
Accident 1469150
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 4 4
Current Violations 2 2 4
Initial Penalty $45,000 $0 $0 $0 $0 $45,000
Current Penalty $27,000 $0 $0 $1,500 $0 $28,500
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3203(A) 12/09/2019 $750 $9,000 $0 01/02/2020 O - Administrative Law Judge Order  
2. 02001 Other 3384(B) 12/09/2019 $750 $9,000 $0 01/02/2020 O - Administrative Law Judge Order  
3. 03001 Serious 4184(B) 12/09/2019 $18,000 $18,000 $0 01/02/2020 O - Administrative Law Judge Order  
4. 04001 Serious 4214(A) 12/09/2019 $9,000 $9,000 $0 01/02/2020 O - Administrative Law Judge Order  

Investigation Summary

Investigation Nr: 121293.015
Event: 06/25/2019
Employee's finger is amputated when glove is caught by bands

At 01:00 a.m. on June 25, 2019, an employee was serving as a newly assigned bandsaw operator using an HE&M Twister Automatic Band Saw, Serial Number 794501, to cut 2-foot lengths of 4-inch by 4-inch rectangular metal tubing. The employee was in the process of cutting the metal tubing with the bandsaw when the blade caught the MaxiFlex glove, model number 24-845 CAT II, on the left hand, drawing it into the blade. The employee sustained an amputation to the left index finger at the proximal interphalangeal joint which included bone loss. The employee was treated and released at Sharp Memorial Hospital on June 25, 2019. At 08:15 a.m. on June 25, 2019, the employer reported the incident incompliance with CSHO requirements. At 09:10 a.m. on August 23, 2019, CSHO arrived on site to begin their investigation and a CCR T8 4184(a) citation for not guarding the point of operation of a machine.

Keywords: Amputation, Bandsaw, Blade, Caught By, Caught In, Cutting, Finger, Glove, Machine operator, Metal Pipe, Operator, Point Of Operation, Saw, Sawblade, Sheet Metal, Unguarded

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1425620.015 30 M Non Hospitalized injury Sawing machine operators
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close