Inspection Detail
Inspection: 1418792.015 - Northern Metal & Roofing Co. Inc.
Inspection Information - Office: Appleton Area Office
Site Address:
Northern Metal & Roofing Co. Inc.
320 Packerland Drive
Green Bay, WI 54303
Mailing Address:
320 Packerland Drive, Green Bay, WI 54303
Union Status: NonUnion
SIC:
NAICS: 238160/Roofing Contractors
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 10/22/2019
Emphasis: L:Piv
Case Closed: 03/02/2020
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1480239 | Yes |
| Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
|---|---|---|---|---|---|---|
| Initial Violations | 1 | 1 | ||||
| Current Violations | 1 | 1 | ||||
| Initial Penalty | $10,210 | $0 | $0 | $0 | $0 | $10,210 |
| Current Penalty | $5,105 | $0 | $0 | $0 | $0 | $5,105 |
| FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
| # | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1. | 01001 | Serious | 19100106 B06 | 11/07/2019 | 12/16/2019 | $5,105 | $10,210 | $0 | I - Informal Settlement |
Investigation Summary
At 11:45 a.m. on July 24, 2019, an employee used a propane torch to heat a tank containing tar. At some point, the valve came off and hot tar and fire blew out of the tank and struck the employee. The employee received burns to the body, arms, and legs and was hospitalized to treat the injuries.
Keywords: Arm, Burn, Heat, Hot Tar, Leg, Propane Torch, Tank, Torso, Valve
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1418792.015 | 18 | M | Hospitalized injury | Installers And Repairers |
Translate