Powered by GoogleTranslate

Inspection Detail

Inspection: 1417443 - Chromalloy Drilling Fluids Corp Div Of Chromalloy

Inspection Information - Office: Houston North Area Office

 

Inspection Nr: 1417443
Report ID: 0626600
Date Opened: 03/26/1985

Site Address:
Chromalloy Drilling Fluids Corp Div Of Chromalloy
229 E Industrial Rd
Liberty, TX 77575

Mailing Address:
P O Drawer 1849, Liberty, TX 77575

Union Status: NonUnion

SIC:2899

NAICS: 0 


Inspection Type: Accident

Scope: Complete

Advanced Notice: Y

Ownership: Private

Safety/Health: Safety

Close Conference: 04/26/1985

Planning Guide: Safety-Manufacturing

Emphasis:

Case Closed: 09/05/1985


Related Activity
Type Activity Nr Safety Health
Accident 360549240
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations
Initial Penalty $490 $0 $0 $0 $0 $490
Current Penalty $0 $0 $0 $0 $0 $0
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100132 A 05/06/1985 05/09/1985 $490 $490 $0 05/16/1985 D - Govt Dismissed Citation has been deleted.

Investigation Summary

Investigation Nr: 14236988
Event: 03/11/1985
ELECTRIC SHOCK AND FALL - DIRECT CONTACT WITH OVERHEAD LINE

TWO EMPLOYEES WERE PREPARING TO SANDBLAST A 22-FOOT HIGH, 8-FOOT DIAMETER TANK LOCATED IN THE YARD AREA OF A WAREHOUSE. TWO TO THREE YEARS EARLIER, THE TANK HAD BEEN SLID INTO ITS PRESENT POSITION UNDER A 7600-VOLT OVERHEAD POWER LINE. THE EMPLOYEES DID NOT HAVE ANY FALL PROTECTION. ONE EMPLOYEE CLIMBED TO THE TOP OF THE TANK. AS HE WAS CLIMBING, HIS HEAD CONTACTED THE POWER LINE. HE LOST CONSCIOUSNESS AND FELL TO THE TANK TOP. THE OTHER EMPLOYEE SAW THE ACCIDENT AND CLIMBED UP TO HELP. HE ALSO TOUCHED THE LINE, WAS ELECTROCUTED, AND FELL OFF THE TANK. A FEW MINUTES LATER, THE FIRST EMPLOYEE ALSO FELL TO THE GROUND.

Keywords: E GI III, OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, ELECTRIC SHOCK, FALL, FALL PROTECTION, TANK

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1417443 Fatality Electric Shock Occupation not reported
2 1417443 Hospitalized injury Electric Shock Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close