Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1416458.015 - Mastec North America, Inc.

Inspection Information - Office: Atlanta West Area Office

 

Inspection Nr: 1416458.015
Report ID: 0418200
Date Opened: 07/18/2019

Site Address:
Mastec North America, Inc.
171 Morgan Dairy Rd
Milner, GA 30257

Mailing Address:
7221 E. Dr. Martin Luther King Jr., Blvd., Tampa, FL 33619

Union Status: NonUnion

SIC:

NAICS: 237130/Power and Communication Line and Related Structures Construction


Inspection Type: Fat/Cat

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/23/2019

Emphasis:

Case Closed: 01/23/2020


Related Activity
Type Activity Nr Safety Health
Accident 1477255
Case Status: CLOSED

Investigation Summary

Investigation Nr: 118062.015
Event: 07/17/2019
Employee working on utility pole is electrocuted

At 4:00 p.m. on July 17, 2019, Employee #1 was working on a power distribution pole. He was attempting to install an L-bracket. As he screwed a nut on the bracket, he was electrocuted.

Keywords: Arm, Burn, Construction, Crossarm, Electrocuted, Installing, Leg, Power Line Worker, Stomach

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1416458.015 29 M Fatality Laborers, except construction
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.