Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1414102.015 - 142846 - Pipeline Utilities, Inc.

Inspection Information - Office: Nc Department Of Labor - Raleigh

 

Inspection Nr: 1414102.015
Report ID: 0453710
Date Opened: 07/10/2019

Site Address:
142846 - Pipeline Utilities, Inc.
104 South Road
Chapel Hill, NC 27514

Mailing Address:
2204 Associate Drive Suite F, Raleigh, NC 27603

Union Status: NonUnion

SIC:1623

NAICS: 237110/Water and Sewer Line and Related Structures Construction


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/31/2019

Emphasis: N:Trench

Case Closed: 12/10/2020


Related Activity
Type Activity Nr Safety Health
Accident 1474397
Referral 1474903 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 2
Current Violations 2 2
Initial Penalty $8,400 $0 $0 $0 $0 $8,400
Current Penalty $0 $0 $0 $8,400 $0 $8,400
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 19260651 K01 11/04/2019 11/08/2019 $4,200 $4,200 $0 01/10/2020 F - Formal Settlement  
2. 01002 Other 19260652 D02 11/04/2019 11/08/2019 $4,200 $4,200 $0 01/10/2020 F - Formal Settlement  

Investigation Summary

Investigation Nr: 117799.015
Event: 07/09/2019
Two employees are injured when struck by support beam

At 10:00 a.m. on July 9, 2019, Employee #1 and Employee #2 were working for a pipeline construction company at a city intersection installing a steam manhole. The employees were working in a 20-foot by 20-foot trench box within a 16-foot deep excavation when the Groundforce Shorco 3M Megabrace System failed. The 3M Megabrace System was not installed per the manufacturer's requirements by not having twelve (12) restraining chains in place to support the Megabraces in the event of a mechanical or hydraulic failure. The employees were struck by a support beam at the base of the trench box when the system collapsed. Employee #1 was struck and pushed away from the beam while Employee #2 was pinned underneath the beam. Employee #1 sustained contusions to his arm while Employee #2 broke his right arm. The local Fire Department, Police, and EMS all responded to the site. Both employees were transported to the Hospital, where they were admitted.

Keywords: Arm, Beam, Collapse, Competent Person, Construction, Contusion, Crushed, Equipment Failure, Excavation, Excavator, Fracture, Installing, Manhole, Pinned, Pipeline, Struck By, Trench, Trench Box, Undrgrd Installation, Unstable Position

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1414102.015 27 M Hospitalized injury Occupation not reported
2 1414102.015 54 M Hospitalized injury Occupation not reported
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.