At 7:00 a.m. on July 8, 2019, an employee working in the construction trades for an industrial engineering contractor was crimping a stator cable. A pin hole was pierced in the hydraulic hose causing fluid to shoot out at high pressure. The employee was injected in the back with hydraulic fluid and was hospitalized.
Keywords: Back, Chemical, Chemical Exposure, Flying Object, High Pressure, Hose, Hydraulic, Hydraulic Equipment, Hydraulic Fluid, Hydraulic Line, Injected, Injection, Pressure, Rupture, Struck By
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1413995.015 | 25 | M | Hospitalized injury | Construction trades, n.e.c. |