Date Opened: 06/26/2019

Site Address:
Community Waste Disposal, Lp
2010 California Crossing
Dallas, TX 75220

Mailing Address:
2010 California Crossing, Dallas, TX 75220

Union Status: NonUnion

SIC:

NAICS: 562219/Other Nonhazardous Waste Treatment and Disposal


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 07/02/2019

Emphasis:

Case Closed: 09/09/2019


Related Activity
Type Activity Nr Safety Health
Referral 1468503 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $13,260 $0 $0 $0 $0 $13,260
Current Penalty $7,956 $0 $0 $0 $0 $7,956
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100147 C01 08/23/2019 09/19/2019 $7,956 $13,260 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 117646.015
Event: 06/22/2019
Employee is burned when CNG line explodes and catches fire

At 9:30 a.m. on June 22, 2019, an employee was performing maintenance on a compressed natural gas (CNG) regulator on a CNG Autocar front end load waste truck. The gas line has an approximately 3600 pounds per square inch (psi) pressure built up in the system. The line was not bled or locked out and it cut loose from the truck causing the shop to catch when the CNG ignited. The employee was burned requiring hospitalization.

Keywords: Arm, Burn, Chest, Compressed Gas, Compressor, Explosion, Fire, Flammable Vapors, Gas, High Pressure, High Pressure Pipe, Lockout, Lockout/Tagout, Maintenance, Malfunction, Mech Malfunction, Natural Gas, Pressure Release, Repair, Valve

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1412919.015 29 M Hospitalized injury Mechanical controls and valve repairers
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.