Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1406329.015 - Dowbuilt Inc.

Inspection Information - Office: Los Angeles District Office

 

Inspection Nr: 1406329.015
Report ID: 0950641
Date Opened: 06/06/2019

Site Address:
Dowbuilt Inc.
28116 W Pacific Coast Highway
Malibu, CA 90265

Mailing Address:
10881 Washington Blvd #204, Culver City, CA 90232

Union Status: NonUnion

SIC:

NAICS: 236118/Residential Remodelers


Inspection Type: Accident

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 11/13/2019

Emphasis:

Case Closed: 02/09/2021


Related Activity
Type Activity Nr Safety Health
Accident 1456803
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1 2
Current Violations 1 1 2
Initial Penalty $16,875 $0 $0 $935 $0 $17,810
Current Penalty $1,125 $0 $0 $935 $0 $2,060
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Other 3384(A) 11/13/2019 $935 $935 $0 12/03/2019 W - Empr Withdrew  
2. 02001 Serious 1509(A) 11/13/2019 11/25/2019 $1,125 $16,875 $0 12/03/2019 O - Administrative Law Judge Order  

Investigation Summary

Investigation Nr: 121615.015
Event: 05/13/2019
Employee's finger is amputated during forming work

At 10:15 a.m. on May 13, 2019, Employee #1 was performing a concrete form assembly for a wall at a residential construction project. Working from a scissor lift at a height of approximately 20 feet, he was inserting coil-rods into a wooden form with ?-inch pre-drilled holes. The employee was wearing Atlas 370 nitrile coated nylon gloves. Employee #1 inserted the 5-foot long threaded fiberglass coil rod into a DeWalt 20 V Max cordless power drill/driver and tightened by using the chuck, similar to the way a bit is inserted into a drill. Then, the employee used his left hand to hold the drill/driver and his free right hand to guide the coil rod into the hole of the form. The tip of the employee's glove became caught in the threads of the fiberglass coil rod, and the glove was spun around the coil, twisting tightly and amputating a portion of the right index finger. The employee was transported to the hospital and admitted for treatment of the amputation of the index finger at the distal interphalangeal joint with residual bone fragments.

Keywords: Broken Bone, Caught By, Caught In, Concrete Form Work, Finger, Forming, Glove, Partial Amputation, Residential Construction, Rotating Drill Bit, Scissor lift, Untrained, Wall

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1406329.015 48 M Hospitalized injury Carpenters
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close