Inspection Detail
Inspection: 1404687.015 - Freeport-Mcmoran Copper & Gold Miami Operations
Inspection Information - Office: Phoenix Area Office
Site Address:
Freeport-Mcmoran Copper & Gold Miami Operations
5701 New Street
Claypool, AZ 85532
Mailing Address:
P.O. Box 4444, Claypool, AZ 85532
Union Status: NonUnion
SIC:
NAICS: 331411/Primary Smelting and Refining of Copper
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/29/2019
Emphasis: L:Smelter
Case Closed: 06/18/2019
| Type | Activity Nr | Safety | Health |
|---|---|---|---|
| Referral | 1459587 | Yes |
Investigation Summary
At 10:15 p.m. on May 25, 2019, an employee was assisting a coworker with changing an anode mold. The employee was standing at the rear of the mold, as his coworker raised the front of the mold with a forklift to set it in place. As the employee reached under the mold with his right hand, he contacting the 600 degree Fahrenheit surface of the mold. The employee sustained 2nd and 3rd degree burns to his hand and was hospitalized.
Keywords: Burn, Contact, Forklift, Glove, Hand, Heat, High Temperature, Industrial Truck, Material Handling, Mold, PPE, Powered Industrial Vehicle, Suspended Load
| # | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 1404687.015 | 32 | M | Hospitalized injury | Mining occupations, n.e.c. |