Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1404652.015 - Pepsi-Cola Bottling Company Of Fort Lauderdale-Palm Beach, Llc

Inspection Information - Office: Fort Lauderdale Area Office

 

Inspection Nr: 1404652.015
Report ID: 0418800
Date Opened: 05/30/2019

Site Address:
Pepsi-Cola Bottling Company Of Fort Lauderdale-Palm Beach, Llc
7305 Garden Road
Riviera Beach, FL 33404

Mailing Address:
7305 Garden Road Attn: Richard Stanton, Riviera Beach, FL 33404

Union Status: NonUnion

SIC:

NAICS: 311930/Flavoring Syrup and Concentrate Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Health

Close Conference: 05/31/2019

Emphasis:

Case Closed: 10/22/2019


Related Activity
Type Activity Nr Safety Health
Referral 1458616 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 3 3
Current Violations 3 3
Initial Penalty $18,943 $0 $0 $0 $0 $18,943
Current Penalty $12,124 $0 $0 $0 $0 $12,124
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 5A0001 06/26/2019 $3,410 $5,683 $0 I - Informal Settlement  
2. 01002 Serious 19100147 C07 III A 06/26/2019 07/30/2019 $5,304 $7,577 $0 I - Informal Settlement  
3. 01003 Serious 19100151 C 06/26/2019 $3,410 $5,683 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 116683.015
Event: 05/23/2019
Employee suffers chemical burns while cleaning tank

At 1:15 a.m. on May 23, 2019, an employee, a batch operator, was cleaning the batching tank equipment. During the cleaning, the new software installed to run the clean in place (CIP) system got stuck in a continuous loop during the caustic wash cycle. The employee aborted the process however, while disconnecting the pipe connecting the CIP system to the batch tank, the caustic solution, Advantis 330, was sprayed on his body. Advantis 330 is a chlorinated alkaline detergent, pH 11.4, for cleaning of stainless steel processing equipment and environmental surfaces encountered in food processing industries. The employee was hospitalized with first and second degree burns to 11% of his torso and back.

Keywords: Back, Chemical Burn, Sprayed, Tank, Tank Cleaning, Torso

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1404652.015 35 M Hospitalized injury Chemical technicians
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close