Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1404041.015 - Hb&G Building Products, Inc.

Inspection Information - Office: Mobile Area Office

 

Inspection Nr: 1404041.015
Report ID: 0418600
Date Opened: 05/29/2019

Site Address:
Hb&G Building Products, Inc.
1015 Brundidge Blvd
Troy, AL 36081

Mailing Address:
P.O. Box 589, Troy, AL 36081

Union Status: NonUnion

SIC:

NAICS: 444190/Other Building Material Dealers


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 05/30/2019

Emphasis:

Case Closed: 07/19/2019


Related Activity
Type Activity Nr Safety Health
Referral 1457652 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 2 1 3
Current Violations 2 1 3
Initial Penalty $14,491 $0 $0 $0 $0 $14,491
Current Penalty $8,600 $0 $0 $0 $0 $8,600
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citaton Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001A Serious 19100147 C04 I 06/07/2019 06/17/2019 $4,000 $6,440 $0 I - Informal Settlement  
2. 01001B Serious 19100212 A01 06/07/2019 $0 $0 $0 I - Informal Settlement  
3. 01002A Serious 19101030 D03 II 06/07/2019 06/17/2019 $4,600 $8,051 $0 I - Informal Settlement  
4. 01002B Serious 19101030 F03 06/07/2019 06/17/2019 $0 $0 $0 I - Informal Settlement  
5. 01002C Serious 19101030 G02 II B 06/07/2019 06/17/2019 $0 $0 $0 I - Informal Settlement  
6. 02001 Other 19101200 F06 II 06/07/2019 06/17/2019 $0 $0 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 116610.015
Event: 05/21/2019
Employee amputates finger in feed line after valve closes

At 11:00 a.m. on May 21, 2019, an employee was using his right hand pinky finger to clean out a metal one inch diameter pipe that feeds organic peroxide catalyst into a mixing bucket. The feed line's pneumatic valve closed on the employee's finger, amputating the fingertip and requiring hospitalization.

Keywords: Amputated, Amputation, Chemical, Cleaning, Finger, Fingertip, Guard, Machine Guarding, Machine operator, Partial Amputation, Pipeline, Pneumatic, Pneumatic system, Regulator Valve, Unguarded, Valve

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1404041.015 33 M Hospitalized injury Supervisors and proprietors, sales occupations
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close