Powered by GoogleTranslate

Inspection Detail

Case Status: CLOSED

Inspection: 1403242.015 - Sekisui Voltek Llc

Inspection Information - Office: Miosha General Industry Safety & Health Division

 

Inspection Nr: 1403242.015
Report ID: 0552652
Date Opened: 05/31/2019

Site Address:
Sekisui Voltek Llc
17 Allen Ave
Coldwater, MI 49036

Mailing Address:
17 Allen Ave, Coldwater, MI 49036

Union Status: NonUnion

SIC:

NAICS: 326150/Urethane and Other Foam Product (except Polystyrene) Manufacturing


Inspection Type: Referral

Scope: Partial

Advanced Notice: N

Ownership: Private

Safety/Health: Safety

Close Conference: 10/29/2019

Emphasis:

Case Closed: 01/08/2020


Related Activity
Type Activity Nr Safety Health
Referral 1458043 Yes
Inspection 1406096 Yes
Inspection 1419460 Yes
Case Status: CLOSED
Violation Summary
Violations/Penalties Serious Willful Repeat Other Unclass Total
Initial Violations 1 1
Current Violations 1 1
Initial Penalty $4,900 $0 $0 $0 $0 $4,900
Current Penalty $2,450 $0 $0 $0 $0 $2,450
FTA Penalty $0 $0 $0 $0 $0 $0

Violation Items
# Citation ID Citation Type Standard Cited Issuance Date Abatement Due Date Current Penalty Initial Penalty FTA Penalty Contest Latest Event Note
1. 01001 Serious 19100303 B07 IV 12/13/2019 $2,450 $4,900 $0 I - Informal Settlement  

Investigation Summary

Investigation Nr: 116700.015
Event: 05/20/2019
Employee incurs electric shock while working near damaged wi

At 11:15 a.m. on May 20, 2019, an employee was using a screwdriver to pry a contaminated foam die collar clamp loose for removal near a damaged electrical conduit and wiring installation on a plastic extrusion machine. The employee was working at approximately chest level standing on some steps when he contacted exposed electrical conductors approximately 6 feet above floor level. The conduit was damaged and insulation was compromised on the wiring on top of the machine when his arm came in contact with the live conductor at 220 volts. The employee sustained an electric shock and was hospitalized.

Keywords: Elec Insulation, Electric Shock, Energized, Maintenance, Plastic Mfg

Investigated Inspection
# Inspection Age Sex Degree of Injury Nature of Injury Occupation
1 1403242.015 40 M Hospitalized injury Machine operators, not specified
Back to Top

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close