Inspection Detail
Inspection: 1402574.015 - Champion Cooler
Inspection Information - Office: Fort Worth Area Office
Site Address:
Champion Cooler
1724 South Scullin Ave
Denison, TX 75020
Mailing Address:
1724 South Scullin Ave, Denison, TX 75020
Union Status: NonUnion
SIC:
NAICS: 333415/Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
Inspection Type: Referral
Scope: Partial
Advanced Notice: N
Ownership: Private
Safety/Health: Safety
Close Conference: 05/21/2019
Emphasis: L:Gifall
Case Closed: 07/08/2019
Type | Activity Nr | Safety | Health |
---|---|---|---|
Referral | 1456160 | Yes |
Violations/Penalties | Serious | Willful | Repeat | Other | Unclass | Total |
---|---|---|---|---|---|---|
Initial Violations | 2 | 2 | ||||
Current Violations | 2 | 2 | ||||
Initial Penalty | $11,934 | $0 | $0 | $0 | $0 | $11,934 |
Current Penalty | $11,934 | $0 | $0 | $0 | $0 | $11,934 |
FTA Penalty | $0 | $0 | $0 | $0 | $0 | $0 |
# | Citation ID | Citaton Type | Standard Cited | Issuance Date | Abatement Due Date | Current Penalty | Initial Penalty | FTA Penalty | Contest | Latest Event | Note |
---|---|---|---|---|---|---|---|---|---|---|---|
1. | 01001 | Serious | 19100023 E01 | 06/11/2019 | 07/10/2019 | $5,304 | $5,304 | $0 | Z - Issued | ||
2. | 01002 | Serious | 19100028 B03 II | 06/11/2019 | 07/10/2019 | $6,630 | $6,630 | $0 | Z - Issued |
Investigation Summary
At approximately 4:00 p.m. on May 16, 2019, an employee was walking on metal grate flooring above a chemical tank. The grate fell and the employee's right foot submerged into the hot chemical. The employee suffered burns and was hospitalized for these injuries.
Keywords: Chemical, Chemical Burn, Foot, Metal grading
# | Inspection | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
---|---|---|---|---|---|---|
1 | 1402574.015 | 26 | M | Hospitalized injury | Painting and paint spraying machine operators |